Stock products delivered fastStock products delivered fast
Free pick up from the Safety Store in HoogvlietFree pick up from the Safety Store in Hoogvliet
Available during the office hours from 07:45 to 17:00Available during the office hours from 07:45 to 17:00

 

 

Rent Respiratory Protection

Looking for respiratory protection? We specialize in respiratory protection rentals and offer a wide range of dependent and independent systems. You can combine your own Life Support Units (LSUs) with our masks and suits, or use our own LSUs and benefit from the advice of our specialists.

 

Our Respiratory Protection Products

Breathing Air Units

Ademlucht units

All Safety provides reliable breathing air solutions and advanced life support units.

 

Breathing Air Accessories

Ademlucht toebehoren

Safe breathing air can be a matter of life and death in sectors such as petrochemicals, manufacturing, and construction.

 

Cleaning and Certification

Reinigen en certificeren

We have a closed-loop system for maintenance, cleaning, and certification. Feel free to come take a look.

 

Customized Respiratory Protection

Working safely in contaminated or low-oxygen environments requires the right respiratory protection. At All Safety, we offer a wide range of rental options, from dependent systems to self-contained breathing apparatus. All our equipment is thoroughly inspected, professionally certified, and ready for immediate use. This ensures that your employees remain protected whenever and wherever necessary.

 

Why Proper Respiratory Protection Is Important

Respiratory protection (RPE) is classified as Category 3 PPE under EU Regulation 2016/425, which implies protection against life-threatening health risks and entails strict requirements for manufacturing, conformity assessment, and quality assurance.

 

Life support units

The gas detection system tests the intake air for abnormalities in O2, CH4, CO, and CO2 levels. If an excessive deviation in the air is detected, the 2x50-liter 300 BAR backup system activates.

Breathing Air Accessories

When using both dependent and independent breathing air, users must wear the appropriate respiratory protective equipment. Each different task requires its own specific protective equipment.

 

 

 

Testing, Cleaning, and Certification

We clean and certify all types of breathing air personal protective equipment on a daily basis. This ensures that you always have certified products in top condition.

Proper use and regular maintenance of RPE are essential for protection. We offer:

  • Fit tests (face fit test): Users must perform a seal check before each use: inhale and exhale, move their head, talk, smile, and bend over—the mask must maintain a tight seal. Facial hair can compromise the seal. This procedure is also known as the respiratory protection fit test and is mandatory for jobs involving high respiratory risks.
  • Instructions for Use and Training: Proper training prevents misuse. Instructions cover proper donning, filter replacement, and recognizing contamination by smell or taste (which indicates that the filter needs to be replaced). These instructions can be included in a respiratory protection toolbox meeting so that employees are well-informed before starting work.
  • Certified maintenance programs: These include cleaning, disinfecting, drying, testing, labeling, and safe storage. Defective or expired masks and filters must be disposed of as chemical waste. Manufacturers offer recycling options.
  • Medical approval and legal compliance: Employers must offer voluntary medical screenings. For firefighters and similar high-risk roles, mandatory breathing apparatus fit tests are required. All protective measures must be documented in the RI&E.

 

 

 

Our selection of respiratory protection equipment for rent or purchase

We offer a wide selection of certified respiratory protection equipment suitable for all risk levels in the workplace:

 Single-use dust masks 
  • FFP1: Light-duty work; no protection against quartz dust
  • FFP2: General work; protects against fine dust
  • FFP3: Heavy-duty work; protects against toxic fine dust
  • Labels: V (valve), R (reusable), NR (non-reusable), D (anti-fog)

Half-face masks

  • Cover the mouth, nose, and chin; available with single or double filters
  • Maintenance-free options also available
  • Typically use P2 or P3 filters; can also be used as escape masks
  • Hypoallergenic materials available

Full-face masks

  • Cover the entire face; equipped with a speaking valve
  • Used in light (spraying), industrial, and firefighting environments
  • Compatible with all combination filters
  • 2 types: full-face mask with air supply and full-face mask with filter

Self-contained systems

  • Air supply via cylinders or compressor (SBCA systems)
  • Ideal for confined spaces or low-oxygen environments
  • Highest level of protection, but limited usage time

Gas filters & combined filters

  • Classified according to EN 14387 color coding (e.g., A = brown, B = gray)
  • Our respiratory protection filters, including ABEK filter cartridges, are suitable for a wide range of hazards.
  • We also offer P2 and P3 respiratory protection filter cartridges, tailored to various working conditions.
  • Special filters available: Hg-P3, NO-P3, CO, SX, Reactor

Powered air-purifying systems

  • Delivers filtered air to hoods or helmets
  • Suitable for dust-intensive industries such as construction, metalworking, and painting

 

 

 

Good Employment Practices Regarding Respiratory Protection

Ensures healthy employees. By offering a voluntary medical examination (without physical exertion), the company physician can issue a written certificate of medical fitness granting approval to work safely with respiratory protection without restrictions. For firefighters, a legally required compressed-air medical examination applies, during which the physical strain associated with wearing respiratory protection is assessed to determine whether it causes or could cause medical limitations. In this context, working with respiratory protection is a requirement or task and is specified in the job description. It is important, however, that the risks and the applicable PPE for respiratory protection are documented in the RI&E.

All Safety has carefully coordinated the above content both internally and externally. The quality assurance of respiratory protective equipment (RPE) thus meets the strictest requirements set forth in the new European Regulation 2016/425. All Safety also guarantees, particularly based on practical experience, targeted, professional, safe, and healthy RPE advice.

 

Discover other rental services from All Safety

 

 

 

 

 

Frequently Asked Questions About Respiratory Protection
What is self-contained breathing apparatus?

Self-contained respiratory protection uses its own air supply, such as a breathing air cylinder or air line. This means you are not dependent on the ambient air and always have access to clean, safe breathing air. This type of protection is used when working in areas with low oxygen levels or hazardous substances.

 

 

What is self-contained breathing apparatus?

Self-contained respiratory protection uses its own air supply, such as a breathing air cylinder or air line. This means you are not dependent on the ambient air and always have access to clean, safe breathing air. This type of protection is used when working in areas with low oxygen levels or hazardous substances.

 

 

Which EU regulations specifically apply to respiratory protection?

Respiratory protection is subject to EU Regulation 2016/425 (Category III, highest risk). Consequently, strict requirements are imposed on production control, conformity assessment procedures, and quality assurance. The purpose of these requirements is to ensure the correct selection and use of respiratory protection to protect users and prevent injury.

The CE marking is a label affixed to the product by the manufacturer, and a Notified Body verifies whether the respiratory protection equipment complies with requirements and standards; the type-examination certificate is valid for a maximum of 5 years.

 

Which EU regulations specifically apply to respiratory protection?

Respiratory protection is subject to EU Regulation 2016/425 (Category III, highest risk). Consequently, strict requirements are imposed on production control, conformity assessment procedures, and quality assurance. The purpose of these requirements is to ensure the correct selection and use of respiratory protection to protect users and prevent injury.

The CE marking is a label affixed to the product by the manufacturer, and a Notified Body verifies whether the respiratory protection equipment complies with requirements and standards; the type-examination certificate is valid for a maximum of 5 years.

 

Can you specify, by industry sector and occupational group(s), which ABM must be worn?

The Working Conditions Act requires a procedure to ensure the right choices are made and adequate protection is provided. This is achieved by always taking the following into account:
1: the substance and the activity or activities to be performed;
2: the results obtained from the RI&E process to guide the occupational hygiene strategy.

If it turns out that source control, technical, collective, and organizational measures are insufficient, respiratory protective equipment (RPE) is used as a control measure. In cases of unknown or high concentrations and in the event of oxygen deficiency, filtering ABMs are insufficient, and independent respiratory protection must always be used.
The specific ABM required depends on the risks associated with the work activities or hazardous substances.

Can you specify, by industry sector and occupational group(s), which ABM must be worn?

The Working Conditions Act requires a procedure to ensure the right choices are made and adequate protection is provided. This is achieved by always taking the following into account:
1: the substance and the activity or activities to be performed;
2: the results obtained from the RI&E process to guide the occupational hygiene strategy.

If it turns out that source control, technical, collective, and organizational measures are insufficient, respiratory protective equipment (RPE) is used as a control measure. In cases of unknown or high concentrations and in the presence of oxygen deficiency, filtering ABMs are insufficient, and independent respiratory protection must always be used.
The specific ABM required depends on the risks associated with the work activities or hazardous substances.

When should you not use respiratory protection with a filter (dependent respiratory protection)?

In the absence of information about concentrations of hazardous substances in the work environment.
If concentrations exceed the filter’s maximum capacity.
When areas are poorly ventilated. Do not enter confined spaces (e.g., a tank) without proper precautions. Always check in advance to ensure the air contains sufficient oxygen (levels are too low at <19 vol-%). In all of the above circumstances, you must wear self-contained breathing apparatus (SCBA) and therefore not a filtering respirator.

When should you not use respiratory protection with a filter (dependent respiratory protection)?

In the absence of information about concentrations of hazardous substances in the work environment.
If concentrations exceed the filter’s maximum capacity.
When areas are poorly ventilated. Do not enter confined spaces (e.g., a tank) without proper precautions. Always check in advance to ensure the air contains sufficient oxygen (levels are too low at <19 vol-%). In all of the above circumstances, you must wear self-contained breathing apparatus (SCBA) and therefore not a filtering respirator.

Which EU regulations specifically apply to respiratory protection?

Respiratory protection is subject to EU Regulation 2016/425 (Category III, highest risk). Consequently, strict requirements are imposed on production control, conformity assessment, and quality assurance. The purpose of these requirements is to ensure the correct selection and use of respiratory protection to protect users and prevent injuries.

Which EU regulations specifically apply to respiratory protection?

Respiratory protection is subject to EU Regulation 2016/425 (Category III, highest risk). Consequently, strict requirements are imposed on production control, conformity assessment, and quality assurance. The purpose of these requirements is to ensure the correct selection and use of respiratory protection to protect users and prevent injuries.

When is respiratory protection required?

Respiratory protection is required if hazardous substances exceed the MAC values or if the oxygen concentration drops below 19%. Organizations must develop a written occupational hygiene program, maintain a list of hazardous chemicals, and ensure proper documentation (RI&E), filter selection, and monitoring. Special work permits and monitoring programs help determine exposure levels.

 

When is respiratory protection required?

Respiratory protection is required if hazardous substances exceed the MAC values or if the oxygen content drops below 19%. Organizations must develop a written occupational hygiene program, maintain a list of hazardous chemicals, and ensure proper documentation (RI&E), filter selection, and monitoring. Special work permits and monitoring programs help determine exposure levels.

 

What types of filters are available for respiratory protection?

Depending on the type of work, various filter cartridges are available. You can choose between P2 or P3 filters for protection against harmful particles, or combined filters that comply with the EN 14387 standard if gases or vapors may also be present.

 

What types of filters are available for respiratory protection?

Depending on the type of work, various filter cartridges are available. You can choose between P2 or P3 filters for protection against harmful particles, or combined filters that comply with the EN 14387 standard if gases or vapors may also be present.

 

Is the use of respiratory protection equipment (RPE) a matter of course for everyone?

No, not everyone can simply use ABM. You must be in decent physical condition, because using ABM places a physical strain on the body. Please also keep the following points in mind: 

  1. Medical limitations: Employees with medical conditions or a relevant medical history (such as heart or lung conditions, or loss of smell or taste) are advised to make an appointment with the company physician.
  2. Physical symptoms: Stop using ABM if you experience dizziness or pain.
  3. Glasses and contact lenses: Employees who wear corrective glasses must use insertable glasses with the appropriate lenses. Contact lenses must not be worn when using full-face respirators; this is unsafe. 

Is the use of respiratory protection equipment (RPE) a matter of course for everyone?

No, not everyone can simply use ABM. You must be in reasonably good physical condition, because using ABM places a physical strain on the body. Please also keep the following points in mind: 

  1. Medical limitations: Employees with medical conditions or a relevant medical history (such as heart or lung conditions, or loss of smell or taste) are advised to make an appointment with the company physician.
  2. Physical symptoms: Stop using ABM if you experience dizziness or pain.
  3. Glasses and contact lenses: Employees who wear corrective glasses must use insertable glasses with the appropriate lenses. Contact lenses must not be worn when using full-face respirators; this is unsafe. 

Questions? Please contact us.

All Safety

Our daily mission is to help ensure a safe working environment for you and your employees. All Safety offers a complete range of support to achieve this goal together with our clients.
© 2026

Need help?

Contact our customer service. We respond within 4 hours on business days.

Don't miss anything!

Do you want to stay informed about all new products and/or offers? Then sign up here!